ZYL Series Gas Rotary Flowmeter

Alle Kategorien
ZYL Series Gas Rotary Flowmeter


Product Overview

ZYL flow metes are designed for metering non-corrosive gases (natural gas, air) in petrochemical, industrial, commercial, and research settings.The meters are compliant with EN12480 and OIML R137. The flow meter Operates on a fixed-displacement rotary principle to measure pipeline gas precisely, with a mechanical counter displaying volumetric flow.

Usage Conditions

Environmental conditions
Ambient temperature:-25℃~+55ºC
Relative humidity:5%~95%
Atmospheric pressure:70 kPa~106 kPa

Medium conditions
Medium temperature:-25℃~55ºC Measuring media: various gases such as natural gas and coal gas, as well as air, alkanes, and industrial inert gases.

Features

High Strength
Robust aluminum alloy housing with thickened walls ensures stress-resistant installation and long-term stability.

Optimized Rotor
Fully meshing arc-envelope rotor design delivers precise sealing and wide measurement range.

Extended Lifespan
Anodized key components resist wear/corrosion.
Non-contact sealing between rotor and housing guarantees durability.

Precision & Reliability
Imported bearings maintain permanent accuracy unaffected by media, ensuring consistent performance.

Wider Range
The range of different specifications can reach 250:1, even up to 260:1

Smaller Starting Flow
The starting flow rate of flowmeters with various specifications ranges from 0.02 m³/h to 0.7 m³/h.

Small Pressure Loss
The pressure loss of flowmeters of diverse specifications varies from 0.05 kPa to 0.8 kPa.

Various Structural Types

A.Basic type: withmechanicalcounter, display of cumulative volume flow under working conditions, and with low-frequency pulse generator. B.Intelligent type: Equipped with volume corrector, with functions of temperature, pressure compensation, wireless remote transmission, IC card, etc.

Specifications
Model DN(mm) FlowRange
(m²/h)
Ratio StartingFlow
(m²/h)
CV
(L)
PressureLoss
(Pa)
G6 20 0.25-10                     40:01:00 0.02 0.22 45
G10
G16
G25
25 0.4-16 40:1 0.02 0.22 50
0.4-25 65:1 0.02 0.22 60
0.4-40 100:1 0.02 0.22 80
G16
G25
40 0.4-25
0.4-40
65:1
100:1
0.02
0.02
0.22
0.22
50
60
G16
G25
G40
G65
50 0.65-25 40:1 0.06 0.7 60
0.65-40
0.65-65
65:1
100:1
0.06
0.06
0.7
0.7
70
260
0.65-100 160:1 0.06 0.7 450
G65
G100
80 0.65-100
0.65-100
160:1
250:1
0.09
0.09
1.1
1.1
180
300
G160 80 1.6-250 160:1 0.15 2.06 350
G160 100 1.6-250 160:1 0.17 2.55 320
G250 100 2.5-400 160:1 0.19 3.97 500
G400 100 4-650 160:1 0.28 3.97 530
G400 150 4-650 160:1 0.6 10.83 680
G650 150 6.5-1000 160:1 0.65 13.38 750
G1000 200 10-1600 160:1 0.7 17.45 800




Accuracy level : 1.0:0.05Qmax≤Q≤Qmax is ±1.0%,Qmin≤Q<0.05Qmax±2.0%

Repeatability:better than 0.2%

Short-term overload:The meter can withstand 1.25Qmax for 30 minutes without damage

Pressure level:1.6MPa

Flange Standard:PN16/Class150